Database Open Access
Abdominal and Direct Fetal ECG Database
Published: Aug. 9, 2012. Version: 1.0.0
Abdominal and Direct Fetal ECG Database (Aug. 9, 2012, 6:30 p.m.)
PhysioBank has received a contribution of five-minute multichannel fetal ECG recordings, with cardiologist-verified annotations of all fetal heart beats, from five women in labor, from the Medical University of Silesia, Poland. Each record includes four signals from the maternal abdomen and a simultaneously recorded reference direct fetal ECG from the fetal scalp; all signals are sampled at 1 KHz with 16-bit resolution.
Please include the standard citation for PhysioNet:
(show more options)
Goldberger, A., Amaral, L., Glass, L., Hausdorff, J., Ivanov, P. C., Mark, R., ... & Stanley, H. E. (2000). PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220.
Abstract
The research material included in the Abdominal and Direct Fetal Electrocardiogram Database contains multichannel fetal electrocardiogram (FECG) recordings obtained from 5 different women in labor, between 38 and 41 weeks of gestation. The recordings were acquired in the Department of Obstetrics at the Medical University of Silesia, by means of the KOMPOREL system for acquisition and analysis of fetal electrocardiogram (ITAM Institute, Zabrze, Poland). Each recording comprises four differential signals acquired from maternal abdomen and the reference direct fetal electrocardiogram registered from the fetal head.
Data Description
The configuration of the abdominal electrodes comprised four electrodes placed around the navel, a reference electrode placed above the pubic symphysis and a common mode reference electrode (with active-ground signal) placed on the left leg. To reduce the skin impedance, the areas under the Ag-AgCl electrodes were abraded. In all cases, the scalp electrode was placed for a clinical indication and all women consented to participate in this study.
The acquisition of direct fetal electrocardiogram was carried out with a typical spiral electrode, commonly used in a direct FECG channel of popular fetal monitors. The R-wave locations were automatically determined in the direct FECG signal by means of on-line analysis applied in the KOMPOREL system. These locations were then verified (off-line) by a group of cardiologists, resulting in a set of reference markers precisely indicating the R-wave locations. The markers have been stored together with the direct and indirect FECG signals in EDF/EDF+ format.
The provided recordings constitute an excellent material for testing and evaluation of efficacy of new FECG processing techniques, e.g. algorithms for suppression of maternal electrocardiogram in abdominal signals or for detection of fetal QRS complexes. In the authors' studies (1-4 above), these recordings were used to evaluate the accuracy of fetal heart rate measurement and to estimate its influence on the quantification of the beat-to-beat fetal heart rate (FHR) variability.
Recording information:
- Signals recorded in labor, between 38 and 41 weeks of gestation
- Four signals acquired from maternal abdomen
- Direct electrocardiogram recorded simultaneously from fetal head
- Positioning of electrodes was constant during all recordings
- Ag-AgCl electrodes (3M Red Dot 2271) and abrasive material to improve skin conductance (3M Red Dot Trace Prep 2236)
- Bandwidth: 1Hz - 150Hz (synchronous sampling of all signals)
- Additional digital filtering for removal of power-line interference (50Hz) and baseline drift
- Sampling rate: 1 kHz
- Resolution: 16 bits
- Input ranges are included in the records in EDF format
Related Publications
- Jezewski J, Matonia A, Kupka T, Roj D, Czabanski R. >Determination of the fetal heart rate from abdominal signals: evaluation of beat-to-beat accuracy in relation to the direct fetal electrocardiogram. Biomedical Engineering/Biomedizinische Technik 2012 Jul;57(5):383-394. doi:10.1515/bmt-2011-0130.
- Matonia A, Jezewski J, Kupka T, Horoba K, Wrobel J, Gacek A. The influence of coincidence of fetal and maternal QRS complexes on fetal heart rate reliability. Medical & Biological Engineering & Computing 2006;44(5):393-403.
- Kotas M, Jezewski J, Horoba L, Matonia A. Application of spatio-temporal filtering to fetal electrocardiogram enhancement. Computer Methods and Programs in Biomedicine. 2011 Oct;104(1):1-9.
- Kotas M, Jezewski J, Matonia A, Kupka T. Towards noise immune detection of fetal QRS complexes. Computer Methods and Programs in Biomedicine. 2010 Mar;97(3):241-256.
Access
Access Policy:
Anyone can access the files, as long as they conform to the terms of the specified license.
License (for files):
Open Data Commons Attribution License v1.0
Discovery
DOI (version 1.0.0):
https://doi.org/10.13026/C2RP4B
Corresponding Author
Files
Total uncompressed size: 14.6 MB.
Access the files
- Download the ZIP file (14.6 MB)
- Access the files using the Google Cloud Storage Browser here. Login with a Google account is required.
-
Access the data using the Google Cloud command line tools (please refer to the gsutil
documentation for guidance):
gsutil -m -u YOUR_PROJECT_ID cp -r gs://adfecgdb-1.0.0.physionet.org DESTINATION
-
Download the files using your terminal:
wget -r -N -c -np https://physionet.org/files/adfecgdb/1.0.0/
-
Download the files using AWS command line tools:
aws s3 sync --no-sign-request s3://physionet-open/adfecgdb/1.0.0/ DESTINATION
Name | Size | Modified |
---|---|---|
ANNOTATORS (download) | 30 B | 2012-08-06 |
RECORDS (download) | 40 B | 2012-12-12 |
SHA256SUMS.txt (download) | 899 B | 2019-02-20 |
r01.edf (download) | 2.9 MB | 2012-08-02 |
r01.edf.qrs (download) | 1.3 KB | 2012-08-02 |
r04.edf (download) | 2.9 MB | 2012-08-02 |
r04.edf.qrs (download) | 1.3 KB | 2012-08-02 |
r07.edf (download) | 2.9 MB | 2012-08-02 |
r07.edf.qrs (download) | 1.3 KB | 2012-08-02 |
r08.edf (download) | 2.9 MB | 2012-08-02 |
r08.edf.qrs (download) | 1.3 KB | 2012-08-02 |
r10.edf (download) | 2.9 MB | 2012-08-02 |
r10.edf.qrs (download) | 1.3 KB | 2012-08-02 |