Cerebral Vasoregulation in Diabetes 1.0.0

File: <base>/Data_Description/GE-71_File_and_channels.csv (9,047 bytes)
VisitPhysionet DirectoryDirectoryProtocolFilenameFormatChannelsSampling rateLabeldescriptionunitsCalibrationEquipmentDevice output sampling rateExperiment
Day 1Not UploadedScreeningICF
PCP permission
Blood draw
Retinal imaging
Day 1Not UploadedTCDTCD window
Day 1Data/Labview/ Head-upTilt_ Day1Head-up tilt testDeep breathing at 0.1Hz
Valsalva maneuver
5-minutes head-up tilt testS#####DA.dat1marker
2ECGECG
3ABPfinger blood pressure waveformmmHg*100Finapress100 HZ
4Mcarright middle cerebral artery flow velocity waveformcm/sMultiempty channels not recorded
5Mcalleft middle cerebral artery flow velocity waveformcm/sMultiDop X4, DWL Neuroscan Inc, Sterling, VA50 Hzempty channels not recorded
6Radiradial artery flow velocity waveformc,/sempty channels not recorded
7Thermstrespiration with nasal thermistorrelativethermisor
8Flow raterespiration flow rateCapnomac Ultima
9O2end tidal O2mmHg*9.09Capnomac Ultima
10CO2end tidal CO2mmHg*7.74Capnomac Ultima
Day 1Not UploadedPortapressBeat-to-beat BPPortapress resting continuous beat-to-beat BP during head-up tilt (day 1) recording
S####D_Portapress.dat
Note: This was recorded during Head-up tilt test. Not all the subjects had a recording.
Note: During recording the machine did not work proprerly, so files which are labeled as Beat1, Beat2, Beat 3 and Beat4. It means those files are from the same subject.
Day 1Data/PedarPedar12 minute Walking testWalk test 1&2 ( walk1 around 11 am and walk 2 in the afternoon, normal hallway walking for 12 min recorded with EMG channels using ME6000) and foot pressure distribution using pedar mobile, some subjects also have Portapress beat-to-beat blood pressure)ME6000
Walking test- foot pressure distribution and walking characteristics using Pedar Mobile
S####DA.ASC_PedarDAT
S####DA.ASC_PedarHEA
16
header: filename, left insole #, right insole #, mean step left, mean step right, min and max step, total time (s econds), distance ( meters),velocity (m/s)
1step_no
2foot
3max. force[N]
4mean force[N]
5max pressure [N/cm²]
6start
7start in % of total time
8stride
9step
10stance
11stance in % of stride
12swing
13swing in %
14init double in %
15single limb support %
16terminate double %
Day 2Data/Labview/ Head-upTilt_ Day2LabviewHead up tiltVasoreactivity, Valsalva maneuver, Head up tilt
TCDwith TCD
Valsalva manuever
5 min supine baselineS####DB.datLabview10500 HzV
3 min hyperventilation
3 min CO2 rebreathing1markerbaselineValsalva maneuverhyperventilationCo2 rebreathinghead-up tiltbaseline
5 min supine rest2ECGECG
Head up tilt 10 min3ABPfinger blood pressure waveformmmHg*100Finapress100 HZ
4Mcarright middle cerebral artery flow velocity waveformcm/sMulti
5Mcalleft middle cerebral artery flow velocity waveformcm/sMultiDop X4, DWL Neuroscan Inc, Sterling, VA; 50 Hz
6Radiradial artery flow velocity waveformc,/s
7Thermstrespiration with nasal thermistorrelativethermisor
8Flow raterespiration flow rateCapnomac Ultima
9O2end tidal O2mmHg*9.09Capnomac Ultima
10CO2end tidal CO2mmHg*7.74Capnomac Ultima
Day 2Data/Labview/Sit-To-Standlabview-sit-to-standSit-to stand with eyes open and closedSit-to-stand Test
5 min sitting with eyes open on balance platform with simultaneous cardiovascular, TCD
5 min standing with eyes open on balance platform with simultaneous cardiovascular, TCD and balance measures
5 min sitting with eyes closed on balance platform with simultaneous cardiovascular, TCD
5 min standing with eyes closed on balance platform with simultaneous cardiovascular, TCD and balance measures
S####DC.datLabview151000 HzV
1markersitting 5minstanding eyes open 3minsittingstanding eyes closed
2ECGECG
3ABPfinger blood pressure waveformmmHg*100Finapress
4Mcarright middle cerebral artery flow velocity waveformcm/sMulti
5Mcalleft middle cerebral artery flow velocity waveformcm/sMultiDop X4, DWL Neuroscan Inc, Sterling, VA;
6Radiradial artery flow velocity waveformcm/s
7Thermstrespiration with nasal thermistorrelativethermisor
8Flow raterespiration flow rateml/sCapnomac Ultima
9O2end tidal O2mmHg*9.09Capnomac Ultima
10CO2end tidal CO2mmHg*7.74Capnomac Ultima
11fxsway trajectory in mediolateral directionmmKistler Force plate, Amherst MA
12fysway trajectory in anteroposterior directionmm
13fzsway trajectory in vertical directionmm
14pxcenter of pressure x componentmm
15pycenter of pressure x componentmm
S#####DC.ch1-10.datLabview101000 Hz
1marker
2ECGECG
3ABPfinger blood pressure waveformmmHg*100Finapress
4Mcarright middle cerebral artery flow velocity waveformcm/sMulti
5Mcalleft middle cerebral artery flow velocity waveformcm/sMultiDop X4, DWL Neuroscan Inc, Sterling, VA;
6Radiradial artery flow velocity waveformcm/s
7Thermstrespiration with nasal thermistorrelativethermisor
8Flow raterespiration flow rateml/sCapnomac Ultima
9O2end tidal O2mmHg*9.09Capnomac Ultima
10CO2end tidal CO2mmHg*7.74Capnomac Ultima
Day 3Not uploaded3T MRIAnatomical MRIMRI- anatomical, CBF regional perfusiona dn paerfusion in vascular territories; CO2 vasoreactivity to hyperventilation and C02 rebreathing
Perfusion MRI3Tesla GE Signa Vhi or Excite scanner and phase arrays head coil ( GE Medical Systmes, Milwaukee, WI)
MP-RAGEMP-RAGE) (repetitionml or % of total brain volume
time [TR]/echo time [TE]/inversion time [TI]  7.8/3.1/600
msec, 3.0 mm slice thickness, 52 slices, bandwidth  122 Hz
per pixel, flip angle  10°, 24 cm  24 cm field of view [FOV],
256  192 matrix size)
FLAIRfluid-attenuated inversion recovery
(FLAIR) (TR/TE/TI  11,000/161/2,250 msec, 5 mm slice
thickness, 30 slices, bandwidth  122 Hz per pixel, flip angle 
90°, 24 cm  24 cm FOV, 256  160 matrix size),
DWIdiffusion-weighted image (b value of 1,000 seconds/
mm2, TR/TE  10,000/86.6 msec, 5 mm slice thickness, bandwidth
 250 kHz, 128  128 matrix size
CASLCBFthree-dimensional stack ofmL · 100 g1 · min1
interleaved spirals fast spin echo sequence (TR/TE  6,000/
23.8 msec, echo train length  66, with a 18  18 cm FOV, in
the coronal plane and 64 slices with thickness  3.8 mm, eight
see Zhao et al. Neurology 2009 ;72:643-649 for procecessing detailsspiral interleaves, two averages and a bandwidth62.5 kHz).
Transcranial Doppler
Day 4Not uploadedNeurological ExaminationThe physician assessed for the presence of neuropathy using the neuropathy checklist.