Classification of Heart Sound Recordings: The PhysioNet/Computing in Cardiology Challenge 2016 1.0.0
(586 bytes)
Segmentation annotations with hand-corrected for PhysioNet/CinC Challenge 2016.
Four states were annotated in the file: S1, systole, S2 and diastole.
each file has two columns:
***************************************
column 1: start point of each state
column 2: state name (S1, systole, S2 and diastole in turn)
the noisy signal segment is annotated as: '(N' for start point and 'N)' for end point
Sample rate: 2,000 Hz
***************************************
--
Chengyu Liu
chengyu.liu@emory.edu
Department of Biomedical Informatics, Emory University, USA.