Database Open Access
The CirCor DigiScope Phonocardiogram Dataset
Jorge Oliveira , Francesco Renna , Paulo Costa , Marcelo Nogueira , Ana Cristina Oliveira , Andoni Elola , Carlos Ferreira , Alipio Jorge , Ali Bahrami Rad , Matthew Reyna , Reza Sameni , Gari Clifford , Miguel Coimbra
Published: May 10, 2022. Version: 1.0.3
When using this resource, please cite:
(show more options)
Oliveira, J., Renna, F., Costa, P., Nogueira, M., Oliveira, A. C., Elola, A., Ferreira, C., Jorge, A., Bahrami Rad, A., Reyna, M., Sameni, R., Clifford, G., & Coimbra, M. (2022). The CirCor DigiScope Phonocardiogram Dataset (version 1.0.3). PhysioNet. https://doi.org/10.13026/tshs-mw03.
Please include the standard citation for PhysioNet:
(show more options)
Goldberger, A., Amaral, L., Glass, L., Hausdorff, J., Ivanov, P. C., Mark, R., ... & Stanley, H. E. (2000). PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220.
Abstract
A total number of 5272 heart sound recordings were collected from the main four auscultation locations of 1568 subjects, aged between 0 and 21 years (mean ± STD = 6.1 ± 4.3 years), with a duration between 4.8 to 80.4 seconds (mean ± STD = 22.9 ± 7.4 s), totaling more than 33.5 hours of recording. Each cardiac murmur in the dataset has been annotated in detail by a human annotator, in terms of timing, shape, pitch, grading, quality and location. Moreover, segmentation annotations regarding the location of fundamental heart sounds (S1 and S2) in the recordings have been obtained using a semi-supervised scheme. The segmentation annotations were performed by voting between three state-of-the-art machine-based algorithms. An expert annotator later studied the consensus and mismatches between the algorithms beat-by-beat and performed a manual annotation whenever the algorithms had disagreed or were not acceptable for the expert. To date, the dataset is the largest publicly available pediatric heart sound dataset, supporting deeper research on the topic of auscultation-based health recommendation systems. The dataset is being used in the George B. Moody PhysioNet Challenge 2022 on Heart Murmur Detection from Phonocardiogram Recordings.
Background
Fundamental heart sounds (namely S1 and S2) are generated from vibrations of the cardiac valves as they open and close during the cardiac cycle. Valve malfunctioning causes turbulence in the blood flow within heart chambers and near the heart, which translates into abnormal sounds known as murmurs. The analysis of murmurs provides invaluable information regarding the functioning status of heart valves. The anatomical position of heart valves relative to the chest wall dictates the optimal auscultation position. As such, for clinical auscultations of each heart valve, the stethoscope is ideally placed at specific locations:
- Aortic valve: second intercostal space, right sternal border
- Pulmonic valve: second intercostal space, left sternal border
- Tricuspid valve: left lower sternal border
- Mitral valve: fifth intercostal space, midclavicular line (cardiac apex)
Blood flowing through these structures creates audible sounds, which are more audible the more turbulent the flow is [1]. The first heart sound (S1) is produced by vibrations of the mitral and tricuspid valves as they close in at the beginning of the systole. S1 is audible at the chest wall and is formed by two components – the mitral and tricuspid [1]. Although the mitral component of S1 is louder and occurs sooner, under physiological resting conditions, both components occur closely enough, making it hard to distinguish them [2]. The second heart sound (S2) is produced by the closure of the aortic and pulmonic valves, at the beginning of the diastole. Similarly to the S1, it is also formed by two components, with the aortic component being louder and occurring sooner than the pulmonic component, due to the pressures in the aorta being higher than in the pulmonary artery. In contrast and unlike S1, under normal conditions the closure sound of the aortic and pulmonic valves can be discernible, due to an increase in venous return during inspiration, which slightly delays the pressure increase in the pulmonary artery and consequently the pulmonic valve closure [3].
Methods
The dataset was collected as part of two mass screening campaigns conducted in Northeast Brazil in July-August 2014 and June-July 2015 [4]. The data collection was approved by the 5192-Complexo Hospitalar HUOC/PROCAPE institutional review board, under the request of the Real Hospital Portugues de Beneficencia em Pernambuco. The target population included all participants presenting voluntarily for screening within the study period. Subjects younger than 21 years of age with a signed parental consent form (where appropriate) were included. A total of 2061 participants attended the 2014 and 2015 “Caravana do Coração” (Portuguese for “Caravan of the Heart”) campaigns, with 493 participants being excluded for not meeting the eligibility criteria. All participants completed a socio-demographic questionnaire and subsequently underwent a clinical examination (anamnesis and physical examination), a nursing assessment (physiological measurements), and cardiac investigations (chest radiography, electrocardiogram, and echocardiogram) when ordered as the result of an examination.
At the end of the examination/screening consultation, the collected data (physical examination, auscultation, echocardiogram, etc.) were analyzed by an expert pediatric cardiologist. If necessary, the experts re-auscultated the patient using their own analog stethoscopes or requested further complementary exams in case of doubts. At the end of the process, if no cardiac pathogenic conditions were observed and there was no need for further surveillance, the patient was discharged by the expert. Alternatively, the patient was either advised for a followup appointment (if there was a heart condition that required medical treatment), or was referred to cardiac catheterization or heart surgery. Patients who underwent heart surgery continued to be monitored, even if they presented no major residual lesions. The subjects with cardiac disease risk factors, such as obesity, diabetes or hypertension were also advised for follow-up visits, regardless of their consultation result. The auscultation process was repeated at every follow-up consultation to monitor the patient's clinical progress, but these data only contain information from the initial screening.
Data quality assessment was performed, and all entries were screened for incorrectly entered or measured values, inconsistent data or outliers, and deleted as appropriate. The resulting entries were then compiled to capture the socio-demographic and clinical variables used in our dataset.
Subsequently, an electronic auscultation was performed and audio samples from four auscultation points were typically collected. All samples were collected by the same operator for the duration of the screening, in a real clinical setting. The resulting phonocardiogram (PCG) audio files were assessed for signal quality and were segmented by cardiac physiologists. The signal quality assessment and segmentations were performed by a different expert in each campaign, and the murmur annotation was performed by the same annotator for the entire dataset (including both campaigns). Overall, 119 participants had recordings that did not meet the required signal quality standards, i.e. these subject recordings did not lead into a reliable murmur characterization and description. These records were considered as unidentifiable (unknown) by the annotator.
The acquired audio records were automatically segmented using the three algorithms proposed in [5], [6] and [7]. These algorithms were only used to detect and identify the fundamental heart sounds (S1 and S2 sounds) and their corresponding boundaries. The aforementioned cardiac physiologists inspected the algorithms’ outputs on mutually exclusive data (as each expert screened only one of the two campaigns). Accordingly, each expert analyzed the automated annotations and whenever the annotator disagreed with the suggested automatic annotations, a manual annotation was required. In such cases, the annotator was instructed to annotate at least five complete heart cycles. Segmentation labels were retained for sections of heart sound recordings that were considered of high quality and representative by the cardiac physiologists. The remainder of the signal may include both low and high quality data. In this way, the users of the dataset may choose to use (or not to use) the suggested time windows, where the signal quality was manually inspected, and the automated labels were validated.
This methodology was applied to both the 2014 and 2015 screening campaigns. A cardiac physiologist manually classified and characterized murmur events blindly, and independent of other clinical notes. The cardiac physiologist inspected by simultaneously listening and visualizing each non-filtered heart sound signal, through the Audacity software. Note that no segmentation data is used by the expert in order to detect and characterize murmur events. The sounds were recorded in an ambulatory environment. Different noisy sources have been observed in our dataset, including stethoscope rubbing noise, speaking, crying, or laughing sounds in the background. On the other hand, the proposed dataset is a representative sample of real-world environments where automatic machine-based auscultation systems may operate. Further details regarding the methodology can be found in [4].
Data Description
There are four data file types in the dataset (per subject):
- A wave recording file (binary
.wav
format) per auscultation location for each subject, which contains the heart sound data - A header file (text
.hea
format) describing the.wav
file using the standard WFDB format [8] - A segmentation data file (text
.tsv
format) per auscultation location for all subjects, which contains segmentation information regarding the start and end points of the fundamental heart sounds S1 and S2 - A subject description text file (text
.txt
format) per subject, where the name of the file corresponds to the subject ID. Demographic data such as weight, height, sex, age group and pregnancy status as well as a detailed description of murmur events are provided in this file.
In addition to the subject-wise description files, the file training_data.csv
contains the overall information for all the records of the training set in the PhysioNet Challenge 2022; this file will not be provided with the Challenge data
The filenames for the audio data, the header file, the segmentation annotation, and the subject description file names are formatted as ABCDE_XY.wav
, ABCDE_XY.hea
, ABCDE_XY.tsv
and ABCDE.txt
, respectively. Here ABCDE
is a numeric subject identifier and XY
is one of the following codes corresponding to the auscultation location where the PCG was collected on the body surface:
PV
corresponds to the pulmonary valve point;TV
corresponds to the tricuspid valve point;AV
corresponds to the aortic valve point;MV
corresponds to the mitral valve point;Phc
for any other auscultation Location.
If more than one recording exists per auscultation location, an integer index succeeds the auscultation location code in the file name, i.e. ABCDE_XY_n.wav
, ABCDE_XY_n.hea
and ABCDE_XY_n.tsv
, where n
is an integer (1, 2, …). Accordingly, each audio file has its own header and annotation segmentation file, but the subject description file ABCDE.txt
is shared between all auscultation recordings of the same subject ID. Multi-location records or repeated records with the same subject ID base name (e.g., ABCDE
as described above), have been recorded in the same session, sequentially. Therefore, the corresponding .wav
files have different lengths and there is no time synchrony between them.
All heart sound records were screened for presence of murmurs at each auscultation location. Each murmur was classified according to its timing (early-, mid-, and late- systolic/diastolic) [9], shape (crescendo, decrescendo, diamond, plateau), pitch (high, medium, low), quality (blowing, harsh, musical) [9], and grade (according to the Levine scale [10]). This information is provided in the subject description files (with .txt
extension), with the following format:
- The first line indicates the subject’s identifier, the number of recordings, and the sampling frequency (in Hz) separated by space delimiters.
- The second line contains information about the heart sound data files corresponding to the current subject ID, also separated by empty spaces. Here the location of the recording (
AV
,PV
,TV
,MV
, orPhc
), the name of the header file, the name of the.wav
file, and the name of the file that includes the information about the segmentation (.tsv
) are included. - The rest of the lines start with a hash symbol (
#
) and indicate the information described in the following table.
Variable |
Description (data type) |
Possible values |
|
Age category (string) |
Neonate |
|
Reported sex (string) |
Female |
|
Height in centimeters (number) |
> 0 |
|
Weight in kilograms (number) |
> 0 |
|
Did the subject report being pregnant at the time of the examination? (boolean) |
True |
|
The second record identifier for subjects that participated to both screening campaigns (string) |
Subject identifier |
|
Campaign attended by the subject (string) |
CC2014 |
|
Indicates if a murmur is present, absent or unidentifiable for the annotator (string) |
Present |
|
Auscultation locations where at least one murmur has been observed (string) |
Any combination of the following abbreviations separated by plus (+) signs: PV, TV, AV, MV, and Phc |
|
Auscultation location where murmurs sounded more intense for the annotator (string) |
PV |
|
Timing of the murmur in the systolic period (string) |
Early-systolic |
|
Shape of the murmur in the systolic period (string) |
Crescendo |
|
Pitch of the murmur in the systolic period (string) |
Low |
|
Grading of the murmur in the systolic period according to the Levine’s scale (string) |
I/VI |
|
Quality of the murmur in the systolic period (string) |
Blowing |
|
Timing of the murmur in the diastolic period (string) |
Early-diastolic |
|
Shape of the murmur in the diastolic period (string) |
Decrescendo |
|
Pitch of the murmur in the diastolic period (string) |
Low |
|
Grading of the murmur in the diastolic period according to the Levine scale (string) |
I/IV |
|
Quality of the murmur in the diastolic period (string) |
Blowing |
|
The expert cardiologist's overall diagnosis |
Normal |
Example 1: The subject description file 1234.txt
contains information about the subject with ID number 1234
, as shown below. Accordingly, there are a total of four wave files for this subject acquired from the locations AV, PV, TV and MV, all sampled at 4000 Hz. Each .wav
file has its murmur segmentation information registered in a separate .tsv
file, with a similar base name as the corresponding .wav
file.
1234 4 4000
AV 1234_AV.hea 1234_AV.wav 1234_AV.tsv
PV 1234_PV.hea 1234_PV.wav 1234_PV.tsv
TV 1234_TV.hea 1234_TV.wav 1234_TV.tsv
MV 1234_MV.hea 1234_MV.wav 1234_MV.tsv
#Age: Child
#Sex: Female
#Height: 123.0
#Weight: 13.5
#Pregnancy status: False
#Murmur: Present
#Murmur locations: AV+MV+PV+TV
#Most audible location: TV
#Systolic murmur timing: Holosystolic
#Systolic murmur shape: Diamond
#Systolic murmur grading: III/VI
#Systolic murmur pitch: High
#Systolic murmur quality: Harsh
#Diastolic murmur timing: nan
#Diastolic murmur shape: nan
#Diastolic murmur grading: nan
#Diastolic murmur pitch: nan
#Diastolic murmur quality: nan
#Outcome: Abnormal
#Campaign: CC2014
#Additional ID: nan
The segmentation annotation file (with .tsv
extension and in plain text format) is composed of three distinct columns: the first column corresponds to the time instant (in seconds), where the wave was detected for the first time; the second column corresponds to the time instant (in seconds) where the wave was detected for the last time; the third column corresponds to an identifier that uniquely identifies the detected wave, with the following convention:
- The S1 wave is identified by the integer 1.
- The systolic period is identified by the integer 2.
- The S2 wave is identified by the integer 3.
- The diastolic period is identified by the integer 4.
- The unannotated segments of the signal are identified by the integer 0.
The file training_data.csv
contains the same information as the subject-wise .txt
files (with the same tags and values), combined in column-wise format for all subjects. Each row of this file corresponds to one subject ID and each column corresponds to one of the subject description tags; this file will not be provided with the Challenge data.
Usage Notes
The dataset is organized in three sets: training, validation, and test sets.
These sets were randomly selected through stratified random sampling over the following classes: normal subjects (absent murmur), abnormal subjects (present murmur) and unsure (unknown murmur absence/presence for the human expert annotator.
We have shared 60% of the dataset publicly as a training set for the George B. Moody PhysioNet Challenge 2022 [11].
We are retaining the remaining 40% of the data privately to score models presented at the PhysioNet Challenge 2022. These data will be released in this project after the end of the Challenge.
In these files, murmur waves are described and categorized per subject and following the same terminology used by physicians, namely its timing, shape, pitch, grading and quality. In addition, the auscultation locations where the murmur is present as well as the auscultation location where the murmur is detected more intensively are also reported in these files.
A short description of the variables extracted from a physical examination and a heart sound auscultation, and the corresponding tags in the description text files are also provided. Note that a description of the murmur is provided in the subject description files only when a murmur is detected in at least one of the subject’s recordings. Thus for healthy subjects no data is provided for those variables, and a single nan
(not a number) symbol is provided.
In the tag Murmur
, each value is of string type and with one of the following outcomes:
- Present: Murmur waves were detected in at least one heart sound recording
- Absent: Murmur waves were not detected in any heart sound recording
- Unknown: The presence or absence of murmurs was unclear for the annotator
The tag Murmurs locations
is a string, each string is a concatenation of acronyms. Each acronym represents an auscultation location where at least one murmur wave has been observed. If more than one location needs to be reported, the locations are listed and separated by plus (+
) signs. The acronyms used to identify the auscultation locations names are: PV
(the pulmonary valve); TV
(tricuspid valve); AV
(aortic valve), MV
(mitral valve), and Phc
for any other auscultation location.
The tag Most audible location
is also a string, each string is a single acronym that identifies the auscultation location where murmur waves were audible more intensively. The acronyms used are the same as in the Murmurs locations
tag.
The tag Systolic murmur timing
is a string and describes the location of the murmur wave in the systolic period. The outcomes are one of the following:
- Early-systolic: a murmur has been observed at the beginning of the systolic period
- Mid-systolic: a murmur has been observed at the middle of the systolic period
- Late-systolic: a murmur has been observed at the ending of the systolic period
- Holosystolic: a murmur has been observed over the whole systolic period
The tag Systolic murmur shape
is a string and describes the shape of the murmur wave that has been observed in the systolic period. The shape of a murmur can be viewed as a function of murmur intensity over time. The possible outcomes for this variable are:
- Crescendo: the amplitude of the murmur wave increases over time
- Decrescendo: the amplitude of the murmur wave decreases over time
- Diamond: the amplitude of the murmur wave first increases for some time but then decreases for the rest of the time period
- Plateau: the amplitude of the murmur wave stays approximately constant over the whole period
The tag Systolic murmur pitch
is a string and it is related to the pressure gradient felt in the heart chambers. In general, the higher the pitch is, the higher is the pressure gradient felt in the corresponding heart chamber. For example, in an aortic stenosis, a large pressure gradient is felt between the left ventricle and the aorta artery. As a result, murmurs generated by an aortic stenosis have in general a high pitch. The possible outcomes are
- High
- Medium
- Low
The tag Systolic murmur grading
is a string and describes the murmur's grade feature from waves observed in the systolic period. This feature is highly correlated with the severity of the murmur. The higher the grading, the worse the patient prognostic and outcome. Since not all subjects have auscultation sounds recorded from all the four main auscultation locations, the approach adopted by the expert annotator to provide grading annotations is as follows:
- Grade I/VI: if barely audible and not heard/present or not recorded in all auscultation locations
- Grade II/VI: if soft, but easily heard in all auscultation locations
- Grade III/VI: if moderately loud or loud. In this dataset, grade III/VI denotes all grade III/VI and above (IV/VI, V/VI, and VI/VI)
Accordingly, the grade annotations can diverge from the original definition of murmur grading, when applied to cases for which not all the auscultation locations are available. In such cases, murmurs were classified by default as grade I/VI. Moreover, the cases classified as grade III/VI, actually include murmurs that could potentially be of grade III/VI or higher, since discrimination among grades III/VI, IV/VI, V/VI, and VI/VI is associated with palpable murmurs, also known as thrills [10], which can only be assessed via in-person physical examination.
The tag Systolic murmur quality
is a string and describes the murmur's quality feature from waves observed in the systolic period. It relates to the presence of harmonics and the overtones. The possible outcomes of this variable are
- Blowing
- Harsh
- Musical
The tag Diastolic murmur timing
is a string and describes the location of the murmur wave in the diastolic period. The possible outcomes of this variable are:
- Early-diastolic: a murmur has been observed at the beginning of the diastolic period
- Mid-diastolic: a murmur has been observed at the middle of the diastolic period
- Holosystolic: a murmur has been observed over the whole diastolic period
The tag Diastolic murmur shape
is a string and describes the shape of the murmur wave that has been observed in the diastolic period. In this database, only murmurs with decrescendo and plateau shapes have been observed in the diastolic period.
The tag Diastolic murmur grading
is a string and describes the murmur's grade feature from waves heard during the diastolic period. In contrast to systolic murmurs, diastolic murmurs do not follow the Levine grading scale [10]. Instead, murmurs are graded from I to IV (instead of I to VI).
- Grade I/IV: if barely audible and not heard/present or not recorded in all auscultation locations
- Grade II/IV: if soft, but easily heard in all auscultation locations
- Grade III/IV: if moderately loud or loud
On the other hand, IV/IV are associated with palpable murmurs, also known as thrills [10], which can only be assessed via physical in-person examination. In this database, Grades III/IV and IV/IV are merged together.
The tag Diastolic murmur pitch
is a string and describes the murmur's pitch feature from waves observed in the diastolic period. The possible outcomes of this variable are
- High
- Medium
- Low
The tag Diastolic murmur quality
is a string and describes the murmur's quality feature from waves heard in the diastolic period. In this dataset, only murmurs with Blowing and Harsh qualities have been heard in the diastolic period.
The tag Sex
is a string and displays the subject’s reported gender. The possible values for this variable are Male or Female, according to the reported gender of the subject at the time of data acquisition. Subjects participating in both CC2014 and CC2015 screening campaigns were consistent in the reported gender and age (taking into account the time/age gap between the two campaigns).
The tag Age
is a string and corresponds to the age category of the subject and according to the National Institute of Child Health and Human Development (NICHD) pediatric terminology [12]. The possible values of this variable are:
- Neonate: birth to 27 days old
- Infant: 28 days old to 1 year old
- Child: 1 to 11 years old
- Adolescent: 12 to 18 years old
- Young Adult: 19 to 21 years old
The tag Height
is a number and corresponds to the subject’s height in centimeters (cm).
The tag Weight
is a number and corresponds to the subject's weight in kilograms (kg).
The tag Pregnancy status
is a boolean variable (True/False) and explicitly identifies the subjects that reported being pregnant at the time of the screening campaign.
Since some subjects attended the two screening campaigns but using a different identifier, the tag Additional ID
provides the second identifier used for the subject.
Since the current dataset is used in the 2022 PhysioNet Challenge on heart murmur detection, in order to remove any data bias in the dataset, data from the same subject (regardless of the screening campaign) is provided either in the training, validation, or testing set (the validation and testing sets not being provided in the current release to comply with the Challenge requirements).
The tag Outcome
is the pediatric cardiologist’s overall assessment of the patient’s cardiac condition, as being Normal or Abnormal. This is a holistic diagnosis based on clinical history, physical examination, analog auscultation, echocardiogram, etc. The cardiologists did not have access to the digital auscultations and the murmur gradings when making these diagnoses, and the indicated outcomes do not necessarily imply that the expert had identified a murmur during analog auscultation. The pediatric cardiologists were not the annotators of the digital auscultations.
The tag Campaign
is a string that identifies the screening campaign that the subject attended. The acronyms used are the following:
- CC2014: the 2014 screening campaign
- CC2015: the 2015 screening campaign
Note that the two screening campaigns have a one-year time gap and taking into account the subjects' age, an open question that requires further study is whether or not any long-term dependencies can be found between the data acquired from the same subjects between the two campaigns. This is left as an open discussion for further evaluation by the scientific community.
Any research/publication based on this database is requested to cite the CirCor DigiScope Phonocardiogram Dataset project on PhysioNet and its corresponding article [4].
Release Notes
Version 1.0.3 made corrections to a missing .tsv
file. The segmentation file 50782_MV.tsv
was removed; 50782_MV_1.tsv
and 50782_MV_2.tsv
were added; 50782.txt
was updated.
Ethics
The data collection was approved by the 5192-Complexo Hospitalar HUOC/PROCAPE institutional review board, under the request of the Real Hospital Portugues de Beneficencia em Pernambuco, Brazil.
Acknowledgements
This work is a result of the Project DigiScope2 (POCI-01-0145-FEDER-029200 - PTDC/CCI-COM/29200/2017), funded by Fundo Europeu de Desenvolvimento Regional (FEDER), through Programa Operacional Competitividade e Internacionalização (POCI), and by national funds, through Fundação para a Ciência e Tecnologia (FCT).
Conflicts of Interest
The authors declare that there are no conflicts of interest.
References
- P. Libby, R. Bonow, D. Mann, and D. Zipes, Braunwald’s Heart Disease: A Textbook of Cardiovascular Medicine. 8th edition. Elsevier Science, 2007.
- J. Soler-Soler and E. Galve, “Worldwide perspective of valve disease,” Heart, vol. 83, no. 6, pp. 721–725, 2000. [Online]. Available: https://dx.doi.org/10.1136/heart.83.6.721
- S. Dornbush and A. E. Turnquest, Physiology, heart sounds (2019) [Online]. Available: In:StatPearls[Internet].TreasureIsland(FL):StatPearlsPublishing, https://www.ncbi.nlm.nih.gov/books/NBK541010/
- J. H. Oliveira, F. Renna, P. Costa, D. Nogueira, C. Oliveira, C. Ferreira, A. Jorge, S. Mattos, T. Hatem, T. Tavares, A. Elola, A. Rad, R. Sameni, G. D. Clifford, & M. T. Coimbra (2021). The CirCor DigiScope Dataset: From Murmur Detection to Murmur Classification. IEEE Journal of Biomedical and Health Informatics, https://doi.org/10.1109/JBHI.2021.3137048
- C. Liu, D. Springer, Q. Li, and et. al., “An open access database for the evaluation of heart sound algorithms,” Physiological Measurement, vol. 37, no. 12, p. 2181, 2016. [Online]. Available: https://doi.org/10.1088/0967-3334/37/12/2181
- J. Oliveira, F. Renna, T. Mantadelis, and M. T. Coimbra, “Adaptive sojourn time HSMM for heart sound segmentation,” IEEE J. Biomed. Health Informatics, vol. 23, no. 2, pp. 642–649, 2019. [Online]. Available: https://doi.org/10.1109/JBHI.2018.2841197
- F. Renna, J. H. Oliveira, and M. T. Coimbra, “Deep convolutional neural networks for heart sound segmentation,” IEEE Journal of Biomedical and Health Informatics, vol. 23, no. 6, pp. 2435–2445, 2019. [Online] Available: https://doi.org/10.1109/JBHI.2019.2894222
- G. Moody, T. Pollard, and B. Moody, “WFDB Software Package (version 10.6.2),” PhysioNet, 2021. https://doi.org/10.13026/zzpx-h016
- S. J. Owen and K. Wong, “Cardiac auscultation via simulation: a survey of the approach of uk medical schools,” BMC research notes, vol. 8, pp. 427–427, Sep 2015, 26358413 [pmid]. [Online] Available: https://doi.org/10.1186/s13104-015-1419-y
- A. Freeman and S. Levine, “The clinical significance of the systolic murmur. a study of 1000 consecutive “non-cardiac” cases,” Ann Intern Med, vol. 6, p. 1371–1385, 1933. [Online]. Available: https://doi.org/10.7326/0003-4819-6-11-1371
- The George B. Moody PhysioNet Challenge 2022: Heart Murmur Detection from Phonocardiogram Recordings. [Online] Available: https://moody-challenge.physionet.org/2022/
- K. Williams, D. Thomson, I. Seto, D. Contopoulos-Ioannidis et al., “Standard 6: Age groups for pediatric trials,” Pediatrics, vol. 129 Suppl 3, pp. S153–60, 06 2012. [Online] Available: http://dx.doi.org/10.1542/peds.2012-0055I
Access
Access Policy:
Anyone can access the files, as long as they conform to the terms of the specified license.
License (for files):
Open Data Commons Attribution License v1.0
Discovery
DOI (version 1.0.3):
https://doi.org/10.13026/tshs-mw03
DOI (latest version):
https://doi.org/10.13026/g02k-a047
Topics:
signal processing
murmur pitch
george b moody physionet challenge 2022
murmur grading
murmur location
murmur timing
phonocardiogram
pregnant
murmur shape
pediatric
murmur detection
murmur intensity
murmur quality
Corresponding Author
Files
Total uncompressed size: 558.9 MB.
Access the files
- Download the ZIP file (449.5 MB)
-
Download the files using your terminal:
wget -r -N -c -np https://physionet.org/files/circor-heart-sound/1.0.3/
-
Download the files using AWS command line tools:
aws s3 sync --no-sign-request s3://physionet-open/circor-heart-sound/1.0.3/ DESTINATION
Name | Size | Modified |
---|---|---|
training_data | ||
LICENSE.txt (download) | 19.9 KB | 2022-05-10 |
RECORDS (download) | 71.1 KB | 2022-01-28 |
SHA256SUMS.txt (download) | 934.9 KB | 2022-05-10 |
training_data.csv (download) | 114.2 KB | 2022-04-28 |