EVAL_ST Tool 1.0.0
(1,499 bytes)
s20511 2 250 17752500 14:32:00 29/11/1998
s20511.dat 212 200/mV 12 0 36 23276 0 V4
s20511.dat 212 200/mV 12 0 33 32443 0 MLIII
#Age: 61 Sex: F
#Comments:
# At 12:28:54 in lead 0 there is an ischemic episode which
# has an episode of noise within it, and the auto-detected
# extrema was falsely placed at the noise location. The
# extrema was relocated manually, and noise annotation was
# added. The same was done in lead 1.
#Symptoms during Holter recording: No data
#Diagnoses:
# Unstable angina,
# Coronary artery disease
#Treatment:
# Medications:
# Nifedipine
# Nitrates
# Aspirin
# Balloon Angioplasty: No data
# Coronary Artery bypass Grafting: No data
#History:
# Resting angina
# Hypertension: No data
# Left ventricular hypertrophy: Septum 13 mm
# Cardiomyopathy: No
# Valve disease: No
# Electrolyte abnormalities: No
# Hypercapnia, anemia, hypotension, hyperventilation: No
# Atrioventricular nodal conduction delay: No
# Intraventricular conduction block: No
# Previous Myocardial Infarction: No
# Previous tests:
# ECG stress test:
# Date: No Data
# Findings: Positive - ST depressions in V4-V6
# Thallium/Stress echo: No data
# Left ventricular function:
# Normal
# Echocardiogram: No data
# Coronary Arteriography:
# Left anterior descending coronary artery 90% stenosis, left circumflex coronary artery 60% stenosis
# Baseline ECG:
# Normal
#Holter Recording:
# Date: 29/11/1998
# Recorder: Remco