Long Term ST Database 1.0.0
(5,480 bytes)
SUMMARY NOTES IN THE RECORD s20601 (Duration: 23:40:00.000)
Starting time, recording date: 14:44:00 11/07/1988
Lead 0: V4
Lead 1: MLIII
Age: 46 Sex: F
Comments:
There is an ischemic episode in lead 1 at 22:22:30
which is corrupted with noise. This patient demonstrated
a few ischemic episodes, manifested by ST depression
in both leads. The changes were minimal, and in some
cases the associated heart rate increases introduced
severe noise.
Symptoms during Holter recording: No data
Diagnoses:
Syndrome X
Treatment:
Medications: None
Balloon Angioplasty: No data
Coronary Artery bypass Grafting: No data
History:
Effort and resting angina
Hypertension: No
Left ventricular hypertrophy: No
Cardiomyopathy: No
Valve disease: No
Electrolyte abnormalities: No
Hypercapnia, anemia, hypotension, hyperventilation: No
Atrioventricular nodal conduction delay: No
Intraventricular conduction block: No
Previous Myocardial Infarction: No
Previous tests:
ECG stress test: Yes
Date: No Data
Findings: Positive for ST depression of 0.1 mV in V3-V6
Thallium/Stress echo: No data
Left ventricular function:
Normal
Echocardiogram: No data
Coronary Arteriography:
Normal coronary tree
Baseline ECG:
Normal
Holter Recording:
Date: 11/07/1988
Recorder: ICR
ST ANNOTATIONS
A. Criteria of 30 seconds and 75 microVolts (s20601.sta)
Lead 0:
Ischemic episodes: 1 Duration: 4:32 0.32%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 0
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 1 Duration: 10:00 0.70%
Lead 1:
Ischemic episodes: 3 Duration: 15:16 1.08%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 1
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 2 Duration: 14:22 1.01%
Total:
Ischemic episodes: 4 Duration: 19:48 0.70%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 1
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 3 Duration: 24:22 0.86%
Combined:
Ischemic episodes: 3 Duration: 15:16 1.08%
Rate-related episodes: 0 Duration: 0:00 0.00%
Unreadable intervals: 2 Duration: 14:22 1.01%
Combined [ischemic or rate-related]:
ST segment episodes: 3 Duration: 15:16 1.08%
Unreadable intervals: 2 Duration: 14:22 1.01%
B. Criteria of 30 seconds and 100 microVolts (s20601.stb)
Lead 0:
Ischemic episodes: 0 Duration: 0:00 0.00%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 0
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 1 Duration: 10:00 0.70%
Lead 1:
Ischemic episodes: 1 Duration: 10:44 0.76%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 1
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 2 Duration: 14:22 1.01%
Total:
Ischemic episodes: 1 Duration: 10:44 0.38%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 1
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 3 Duration: 24:22 0.86%
Combined:
Ischemic episodes: 1 Duration: 10:44 0.76%
Rate-related episodes: 0 Duration: 0:00 0.00%
Unreadable intervals: 2 Duration: 14:22 1.01%
Combined [ischemic or rate-related]:
ST segment episodes: 1 Duration: 10:44 0.76%
Unreadable intervals: 2 Duration: 14:22 1.01%
C. Criteria of 60 seconds and 100 microVolts (s20601.stc)
Lead 0:
Ischemic episodes: 0 Duration: 0:00 0.00%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 0
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 1 Duration: 10:00 0.70%
Lead 1:
Ischemic episodes: 1 Duration: 10:44 0.76%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 1
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 2 Duration: 14:22 1.01%
Total:
Ischemic episodes: 1 Duration: 10:44 0.38%
Rate-related episodes: 0 Duration: 0:00 0.00%
Axis shifts: 1
Conduction-change shifts: 0
Noisy events: 0
Unreadable intervals: 3 Duration: 24:22 0.86%
Combined:
Ischemic episodes: 1 Duration: 10:44 0.76%
Rate-related episodes: 0 Duration: 0:00 0.00%
Unreadable intervals: 2 Duration: 14:22 1.01%
Combined [ischemic or rate-related]:
ST segment episodes: 1 Duration: 10:44 0.76%
Unreadable intervals: 2 Duration: 14:22 1.01%
QRS ATRUTH ANNOTATIONS (s20601.atr)
Total number of beats 116943
Normal beats 116941
Premature ventricular contractions 2