mgh051 8 360/0.476 1360800 12:33:29 11/10/1992
mgh051.dat 212 400(500)/mV 12 0 451 16898 0 ECG lead I
mgh051.dat 212 400/mV 12 0 48 14183 0 ECG lead II
mgh051.dat 212 400/mV 12 0 80 24944 0 ECG lead V
mgh051.dat 212 11.77(-1303)/mmHg 12 0 48 15482 0 ART
mgh051.dat 212 18.98(-994)/mmHg 12 0 -931 19347 0 PAP
mgh051.dat 212 20 12 0 -963 -448 0 CVP
mgh051.dat 212 1000 12 0 90 16439 0 Resp. Imp.
mgh051.dat 212 1000 12 0 1112 -2884 0 CO2
#<age>: 10 <sex>: M
# Aortic and mitral valve replacements for valvular stenosis
# Coronary artery bypass graft
# PHARMACOLOGIC SUPPORT:
# Dopamine @ 250 mcg/min
# TNG @ 83 mcg/min
# Levophed @ .75 mcg/min
# GENERAL COMMENTS:
# Stop/FFW 14 min - 15 min
# ELECTROCARDIOGRAPHIC DATA:
# UNDERLYING RHYTHM:
# Atrial fibrillation with 1: 1 intraventricular conduction defect and ventricular demand pacing
# PACEMAKER DATA:
# Temporary ventricular demand pacing (WI)
# Epicardial wires
# Medtronic A-V sequential pacer
# MA 13
# ECG INTERPRETATION:
# Low voltage
# Nonspecific ST segment and T wave abnormalities
# HEMODYNAMIC DATA:
# ART: 106/36
# PAP: 36/18
# RAP: 11 Cl: 2.4
# TECHNICAL COMMENTS:
# PAP/CVP/LAP on same transducer
# PAP recordings @ 16 min - 19 min and 26 min
# CVP recordings @ 19 min - 22 min and 33 min
# LAP recordings @ 24 min - 25 min and 33 min
# No pop-test on combined pressure channel
# RESPIRATORY DATA:
# RATE: B/B changed to 6 bpm @ 23 min
# MODE OF VENTILATION:
# Intermittent mandatory ventilation