MGH/MF Waveform Database 1.0.0
(1,420 bytes)
mgh057 8 360/0.476 1296000 12:41:16 25/06/1991
mgh057.dat 212 272(-331)/mV 12 0 -339 28835 0 ECG lead I
mgh057.dat 212 252(-118)/mV 12 0 -12 -27663 0 ECG lead II
mgh057.dat 212 238(-35)/mV 12 0 -44 27190 0 ECG lead V
mgh057.dat 212 11.99(-1460)/mmHg 12 0 -10 11776 0 ART
mgh057.dat 212 20.84(-1288)/mmHg 12 0 -1020 18395 0 PAP
mgh057.dat 212 20 12 0 -1025 18891 0 CVP
mgh057.dat 212 1000 12 0 -36 -27812 0 Resp. Imp.
mgh057.dat 212 1000 12 0 936 18286 0 CO2
#<age>: 57 <sex>: M <diagnoses>: Coronary artery bypass graft
# PHARMACOLOGIC SUPPORT:
# TNG @ 36 mcg/min, then off
# ELECTROCARDIOGRAPHIC DATA:
# UNDERLYING RHYTHM:
# Atrial pacing @ 96 bpm (AOO)
# PACEMAKER INFO:
# Temporary atrial fixed rate pacing
# Epicardial wires
# Medtronic S837 pulse generator
# MA 14.96
# ECG INTERPRETATION:
# Inferior and anterior infarcts
# Low voltage
# Nonspecific ST segment and T wave abnormalities
# TECHNICAL COMMENTS:
# Intermittent 6O-cycle interference
# HEMODYNAMIC DATA:
# ART: 114/56 MEAN: 88
# PAP: 38/16
# RAP: 14 LAP: 16 CO: 3.4
# INTRA-AORTIC BALLOON DATA:
# 40 cc ballon
# Kontron console
# 1:1 balloon ratio
# WAVEFORM PATTERNS:
# Aortic lumen and radial arterial IABP trace
# TECHNICAL COMMENTS:
# Aortic lumen damping, flushed
# PA recording @ 19 min - 23 min
# RESPIRATORY DATA:
# RATE: 7/7 bpm
# MODE OF VENTILATION:
# Controlled
# CO2 RECORDING