MGH/MF Waveform Database 1.0.0

File: <base>/mgh120.hea (1,252 bytes)
mgh120 8 360/0.476 1604880 10:34:14 07/08/1991
mgh120.dat 212 276(-364)/mV 12 0 -354 -11426 0 ECG lead I
mgh120.dat 212 247(-18)/mV 12 0 0 17534 0 ECG lead II
mgh120.dat 212 207(-22)/mV 12 0 -7 -28564 0 ECG lead V
mgh120.dat 212 12(-1420)/mmHg 12 0 2 -245 0 ART
mgh120.dat 212 20 12 0 -1012 16037 0 PAP
mgh120.dat 212 20 12 0 -1013 -10408 0 CVP
mgh120.dat 212 1000 12 0 6 20590 0 Resp. Imp.
mgh120.dat 212 1000 12 0 1008 13027 0 CO2
#<age>: 65 <sex>: F <diagnoses>: Mitral and tricuspid valve replacements
# PHARMACOLOGIC SUPPORT
#   Dopamine @ 90 mcg/min
# GENERAL COMMENTS:
#   Bed change @ 41 min
#   Suctioning @ 57 min
# ELECTROCARDIOGRAPHIC DATA:
# UNDERLYING RHYTHM:
#   Atrial flutter with incomplete right bundle branch block @ 82 bpm
# RHYTHM DISTURBANCES:
#   Occasional aberrant conduction
#   Multifocal ventricular ectopy
# ECG INTERPRETATION:
#   Left ventricular hypertrophy
#   ST segment and T wave changes
#   Possible anterior ischemia
# HEMODYNAMIC DATA:
#   ART: 120/44
#   RAP: 18
# TECHNICAL COMMENTS:
#   CVP on @ 32 min - 41 min
#   Pressure transducers disconnected @ 65 min
#   No zero/col/pop-test sequence
# RESPIRATORY DATA:
# RATE:   Not documented
# MODE OF VENTILATION:
#   Intermittent mandatory ventilation