MGH/MF Waveform Database 1.0.0
(1,442 bytes)
mgh179 8 360 1200960 7:26:36 06/06/1991
mgh179.dat 212 250 12 0 -319 5899 0 ECG lead I
mgh179.dat 212 250 12 0 -8 6788 0 ECG lead II
mgh179.dat 212 250 12 0 -30 26177 0 ECG lead V
mgh179.dat 212 12(-1214)/mmHg 12 0 -5 11637 0 ART
mgh179.dat 212 17.58(-1099)/mmHg 12 0 -1043 19511 0 PAP
mgh179.dat 212 20 12 0 -1038 683 0 CVP
mgh179.dat 212 1000 12 0 -26 15966 0 Resp. Imp.
mgh179.dat 212 1000 12 0 -994 -29545 0 CO2
#<age>: 72 <sex>: F <diagnoses>: Chronic obstructive lung disease with pneumonia
# PHARMACOLOGIC SUPPORT:
# Neosynephrine @ 59 mcg/min
# GENERAL COMMENTS:
# Power to monitor off @ 27 min - 28 min
# Data collection ends @ 45 min
# Final zero/cal pop test sequence @ 45 min - 50 min
# Stop/FFW @ 52 min - 53 min
# ECG recorded during chest physical therapy @ 53 min-end
# ELECTROCARDIOGRAPHIC DATA:
# UNDERLYING RHYTHM:
# Normal sinus rhythm @ 87 bpm
# ECG INTERPRETATION:
# Nonspecific ST segment and T wave abnormalities
# TECHNICAL COMMENTS:
# Wandering baseline
# Electrodes replaced @ 52 min
# HEMODYNAMIC DATA:
# ART: 110/60 (axillary)
# PAP: 65/27 (39) PCW: 12 (@ 10 min, 18 min, 20 min, 52 min,= best)
# RAP: 8 CO: 4.35
# WAVEFORM PATTERNS:
# Pulmonary hypertension
# Respiratory variation
# TECHNICAL COMMENTS:
# PA and CVP on same transducer
# CVP @ 16 min - 19 min
# RESPIRATORY DATA:
# RATE: 12/20 bpm
# MODE OF VENTILATION:
# Intermittent mandatory ventilation