MGH/MF Waveform Database 1.0.0

File: <base>/mgh210.hea (1,888 bytes)
mgh210 8 360/0.476 1786197  7:57:37 24/07/1991
mgh210.dat 212 127(-338)/mV 12 0 -331 -13212 0 ECG I
mgh210.dat 212 295(-45)/mV 12 0 6 14865 0 ECG II
mgh210.dat 212 250 12 0 -4 14042 0 ECG III
mgh210.dat 212 10 12 0 10 -10254 0 Pressure1
mgh210.dat 212 10 12 0 7 24840 0 Pressure 2
mgh210.dat 212 10 12 0 -3 -29646 0 Pressure
mgh210.dat 212 10 12 0 18 -11147 0 Pressure
mgh210.dat 212 1000 12 0 34 9226 0 No signal
#<age>: 32 <sex>: M <diagnoses>: Congenital heart disease (corrected Tetralogy of Fallot); Coronary heart disease
# PROCEDURE:
#   Right heart cath/left heart cath/coronary angiography
# ECG DATA:
# LEADS:   I (telemetry), II, III
# RHYTHM:
#   Ventricular pacing
# PACEMAKER INFORMATION:
#   Permanent WI pacer
# RHYTHM CHANGES:
#   Multifocal ventricular ectopy with couplets and runs of tachycardia
# ECG INTERPRETATION:
#   Probable ventricular atrial conduction
# HEMODYNAMIC DATA:
#   ART: 100/70
#   PA: 40/20 (30)   	PCW: 26
#   CVP: 30
# PROCEDURAL EVENTS:     RHYTHM/PRESSURE CHANGES:
# 	SET-UP
# 0-18 sec	CAL TO ECG AND TELEMETRY
# 18-27 sec
# 	STOP/FFW
# 1 min	ATTACH CATHETER CH8
# 1 min	ATTACH CATHETER CH9
# 6 min	CAL OF 200 CH9
# 6 min	CAL OF 200 CH8
# 6 min	ZERO
# 9 min	PA INSERTION     RA/RV /PA/PCW
# 12 min	CATHETER IN PA OUTFLOW TRACT
# 17 min	ZERO
# 		RA TRACE
# 		RV/PA TRACE
# 30 min	PA CATHETER OUT
# 34 min	RE-ZERO CH9
# 34 min	CATHETER TO DESCENDING AORTA
# 	AO(CH9)
# 35 min	RE-ZERO CH8
# 35 min	CATHETER TO FEMORAL ARTERY
# 	ART(CH8)
# 36 min
# 	LV/FEMORAL
# 43 min	RE-ZERO CH8
# 44 min	POSITION IN RV     RV
# 	INSERT RIGHT HEART CATHETER
# 	RE-ZERO
# 44 min		LV/RV
# 46 min		PA
# 46 min		LV
# 49 min	PULLBACK PA TO RV   PA/RV
# 49 min	PULLBACK RV TO RA   RV/RA
# 54 min		PCW (CH 8)
# 55 min		PCW
# 59 min	RE-ZERO CH 8
# 59 min	PULLBACK
# 77 min	TEST DOSE
# 78 min	RV GRAM   RV