MGH/MF Waveform Database 1.0.0
(1,888 bytes)
mgh210 8 360/0.476 1786197 7:57:37 24/07/1991
mgh210.dat 212 127(-338)/mV 12 0 -331 -13212 0 ECG I
mgh210.dat 212 295(-45)/mV 12 0 6 14865 0 ECG II
mgh210.dat 212 250 12 0 -4 14042 0 ECG III
mgh210.dat 212 10 12 0 10 -10254 0 Pressure1
mgh210.dat 212 10 12 0 7 24840 0 Pressure 2
mgh210.dat 212 10 12 0 -3 -29646 0 Pressure
mgh210.dat 212 10 12 0 18 -11147 0 Pressure
mgh210.dat 212 1000 12 0 34 9226 0 No signal
#<age>: 32 <sex>: M <diagnoses>: Congenital heart disease (corrected Tetralogy of Fallot); Coronary heart disease
# PROCEDURE:
# Right heart cath/left heart cath/coronary angiography
# ECG DATA:
# LEADS: I (telemetry), II, III
# RHYTHM:
# Ventricular pacing
# PACEMAKER INFORMATION:
# Permanent WI pacer
# RHYTHM CHANGES:
# Multifocal ventricular ectopy with couplets and runs of tachycardia
# ECG INTERPRETATION:
# Probable ventricular atrial conduction
# HEMODYNAMIC DATA:
# ART: 100/70
# PA: 40/20 (30) PCW: 26
# CVP: 30
# PROCEDURAL EVENTS: RHYTHM/PRESSURE CHANGES:
# SET-UP
# 0-18 sec CAL TO ECG AND TELEMETRY
# 18-27 sec
# STOP/FFW
# 1 min ATTACH CATHETER CH8
# 1 min ATTACH CATHETER CH9
# 6 min CAL OF 200 CH9
# 6 min CAL OF 200 CH8
# 6 min ZERO
# 9 min PA INSERTION RA/RV /PA/PCW
# 12 min CATHETER IN PA OUTFLOW TRACT
# 17 min ZERO
# RA TRACE
# RV/PA TRACE
# 30 min PA CATHETER OUT
# 34 min RE-ZERO CH9
# 34 min CATHETER TO DESCENDING AORTA
# AO(CH9)
# 35 min RE-ZERO CH8
# 35 min CATHETER TO FEMORAL ARTERY
# ART(CH8)
# 36 min
# LV/FEMORAL
# 43 min RE-ZERO CH8
# 44 min POSITION IN RV RV
# INSERT RIGHT HEART CATHETER
# RE-ZERO
# 44 min LV/RV
# 46 min PA
# 46 min LV
# 49 min PULLBACK PA TO RV PA/RV
# 49 min PULLBACK RV TO RA RV/RA
# 54 min PCW (CH 8)
# 55 min PCW
# 59 min RE-ZERO CH 8
# 59 min PULLBACK
# 77 min TEST DOSE
# 78 min RV GRAM RV