PTB Diagnostic ECG Database 1.0.0

File: <base>/patient224/s0447_re.hea (2,503 bytes)
s0447_re 15 1000 120012
s0447_re.dat 16 2000 16 0 504 7430 0 i
s0447_re.dat 16 2000 16 0 210 -14539 0 ii
s0447_re.dat 16 2000 16 0 -294 11909 0 iii
s0447_re.dat 16 2000 16 0 -357 -3867 0 avr
s0447_re.dat 16 2000 16 0 398 4407 0 avl
s0447_re.dat 16 2000 16 0 -42 31575 0 avf
s0447_re.dat 16 2000 16 0 191 2039 0 v1
s0447_re.dat 16 2000 16 0 -562 -4958 0 v2
s0447_re.dat 16 2000 16 0 119 5037 0 v3
s0447_re.dat 16 2000 16 0 -715 4617 0 v4
s0447_re.dat 16 2000 16 0 521 23611 0 v5
s0447_re.dat 16 2000 16 0 2137 -26450 0 v6
s0447_re.xyz 16 2000 16 0 1344 5706 0 vx
s0447_re.xyz 16 2000 16 0 -664 -31545 0 vy
s0447_re.xyz 16 2000 16 0 604 -5131 0 vz

# age: 38
# sex: female
# ECG date: 04/06/1996

# Diagnose:
# Reason for admission: Valvular heart disease
# Acute infarction (localization): no
# Former infarction (localization): no
# Additional diagnoses: AV-reentry tachycardia, Prosthetic aortic valve replacement (post Endocarditis) actual gradient=64mmHg 
# Smoker: no
# Number of coronary vessels involved: unknown
# Infarction date (acute): n/a
# Previous infarction (1) date: n/a
# Previous infarction (2) date: n/a

# Hemodynamics:
# Catheterization date: n/a
# Ventriculography: n/a
# Chest X-ray: n/a
# Peripheral blood Pressure (syst/diast): n/a
# Pulmonary artery pressure (at rest) (syst/diast): n/a
# Pulmonary artery pressure (at rest) (mean): n/a
# Pulmonary capillary wedge pressure (at rest): n/a
# Cardiac output (at rest): n/a
# Cardiac index (at rest): n/a
# Stroke volume index (at rest): n/a
# Pulmonary artery pressure (laod) (syst/diast): n/a
# Pulmonary artery pressure (laod) (mean): n/a
# Pulmonary capillary wedge pressure (load): n/a
# Cardiac output (load): n/a
# Cardiac index (load): n/a
# Stroke volume index (load): n/a
# Aorta (at rest) (syst/diast): n/a
# Aorta (at rest) mean: n/a
# Left ventricular enddiastolic pressure: n/a
# Left coronary artery stenoses (RIVA): n/a
# Left coronary artery stenoses (RCX): n/a
# Right coronary artery stenoses (RCA): n/a
# Echocardiography: Good global contractility.Maximal instantaneous pressure gradient across aortic valve prosthesis 63 mmHg, mean gradient 34 mmHg

# Therapy:
# Infarction date: n/a
# Catheterization date: n/a
# Admission date: n/a
# Medication pre admission: n/a
# Start lysis therapy (hh.mm): n/a
# Lytic agent: n/a
# Dosage (lytic agent): n/a
# Additional medication: n/a
# In hospital medication: n/a
# Medication after discharge: n/a