Database Open Access
Siena Scalp EEG Database
Published: Aug. 11, 2020. Version: 1.0.0
When using this resource, please cite:
(show more options)
Detti, P. (2020). Siena Scalp EEG Database (version 1.0.0). PhysioNet. https://doi.org/10.13026/5d4a-j060.
Please include the standard citation for PhysioNet:
(show more options)
Goldberger, A., Amaral, L., Glass, L., Hausdorff, J., Ivanov, P. C., Mark, R., ... & Stanley, H. E. (2000). PhysioBank, PhysioToolkit, and PhysioNet: Components of a new research resource for complex physiologic signals. Circulation [Online]. 101 (23), pp. e215–e220.
Abstract
The database consists of EEG recordings of 14 patients acquired at the Unit of Neurology and Neurophysiology of the University of Siena. Subjects include 9 males (ages 25-71) and 5 females (ages 20-58). Subjects were monitored with a Video-EEG with a sampling rate of 512 Hz, with electrodes arranged on the basis of the international 10-20 System. Most of the recordings also contain 1 or 2 EKG signals. The diagnosis of epilepsy and the classification of seizures according to the criteria of the International League Against Epilepsy were performed by an expert clinician after a careful review of the clinical and electrophysiological data of each patient.
Background
Epilepsy is interpreted as a neurological disorder characterized by the occurrences of seizures, due to abnormal excessive or synchronous neuronal activity in the brain [1]. Very importantly, the main features of epilepsy, epileptic seizures, are associated with a number of negative consequences at both short- and long-term, including the risk of falls and injuries, eventually death, psychiatric disturbances, cognitive deficits and difficulties in achieving academic, social and employment goals. Treatment options for epilepsy are pharmacological and surgical.
However, antiepileptic drugs have limitations [2] and fail to control seizures in roughly 30% of patients, while surgery is not always an option. In this context, an important issue is the possibility of predicting/detecting the occurrences of epileptic seizures (i.e., detecting a preictal or pre-seizure state), in order to take actions to neutralize an incoming seizure or limit the injuries (e.g., by warning alarms, applying short-acting drugs, activating stimulating devices).
The data has been collected by the Unit of Neurology and Neurophysiology at University of Siena, Italy, during a regional research project, called PANACEE [3], aiming at the development of noninvasive patient-specific monitoring/control low-cost devices for the prediction of epileptic seizures.
Methods
The database consists of EEG recordings of 14 patients monitored with a Video-EEG with a sampling rate of 512 Hz, with electrodes arranged on the basis of the international 10-20 System. All the recordings contain 1 or 2 EKG signals, too. The data were acquired employing EB Neuro and Natus Quantum LTM amplifiers, and reusable silver/gold cup electrodes. Patients were asked to stay in the bed as much as possible, either asleep or awake.
The Ethical Committee of the University of Siena approved the data in accordance with the Declaration of Helsinki. At the time of admission at the clinics, each patient signed a written informed consent in which agrees to the video registration and to the use of the data for a possible scientific divulgation.
Data Description
The database consists of 14 folders containing EEG recordings in EDF format (European Data Format). Each folder refers to a specific subject including between 1 and 5 data files with a maximum size of 2.11 GB each, and a text file containing information on data and seizures. The edf files contain signals recorded on the same or different days and the seizure events are chronologically ordered. All dates in the .edf
files are de-identified.
The file subject_info.csv
contains, for each subject, the gender and age, the seizure classification according to the criteria of the International League Against Epilepsy, the number of EEG channels, the number of seizures and the total recording time in minutes. IAS
is focal onset impaired awareness; WIAS
is focal onset without impaired awareness; FBTC
is focal to bilateral tonic-clonic; T
is temporal; R
is right; L
is left. In total, the database contains 47 seizures on about 128 recording hours.
Usage Notes
Each folder contains from 1 to 5 edf data files containing EEG and EKG recordings of a specific subject. Each folder also includes a text file named Seizures-list-PNxx.txt
containing: data sampling rate (in Hz); the list of the channels from which the EEG and EKG signals are extracted (all other channels in the edf files must be ignored); start and end time of recording, start and end time of each seizure, in the format hours.minutes.seconds.
Noninvasive EEG data may be useful for exploring the possibility of developing a noninvasive monitoring/control devices for the prediction of seizures. The data have been presented in Detti et al [4] and employed for validating seizure prediction algorithms in [4,5,6].
Conflicts of Interest
The authors have no conflicts of interest to declare.
References
- Epilepsy Foundations, Last accessed on July 17th, 2020. https://www.epilepsy.com/
- CLP Deckers et al. (2003). Current limitations of antiepileptic drug therapy: a conference review. Epilepsy research, 53(1-2):1–17.
- PANACEE project, Last accessed on July 17th, 2020. https://panacee. diism.unisi.it/
- Detti, P., Vatti, G., & Zabalo Manrique de Lara, G. (2020). EEG synchronization analysis for seizure prediction: a study on data of non-invasive recordings. Processes, 8(7), doi.org/10.3390/pr8070846.
- Detti, P., Lara, G. Z., Bruni, R., Pranzo, M., Sarnari, F., & Vatti, G. (2018). A Patient-specific Approach for Short-term Epileptic Seizures Prediction through the Analysis of EEG synchronization. IEEE Transactions on Biomedical Engineering, 1-1. doi:10.1109/tbme.2018.2874716.
- Billeci, L, Marino, D, Insana, L, Vatti, G, & Varanini, M. (2018). Patient-specific seizure prediction based on heart rate variability and recurrence quantification analysis. PLoS One. 13(9). doi: 10.1371/journal.pone.0204339. eCollection 2018.
Access
Access Policy:
Anyone can access the files, as long as they conform to the terms of the specified license.
License (for files):
Creative Commons Attribution 4.0 International Public License
Discovery
DOI (version 1.0.0):
https://doi.org/10.13026/5d4a-j060
DOI (latest version):
https://doi.org/10.13026/s309-a395
Corresponding Author
Files
Total uncompressed size: 20.3 GB.
Access the files
- Download the ZIP file (13.0 GB)
-
Download the files using your terminal:
wget -r -N -c -np https://physionet.org/files/siena-scalp-eeg/1.0.0/
-
Download the files using AWS command line tools:
aws s3 sync --no-sign-request s3://physionet-open/siena-scalp-eeg/1.0.0/ DESTINATION
Name | Size | Modified |
---|---|---|
Parent Directory | ||
PN05-2.edf (download) | 334.1 MB | 2018-11-06 |
PN05-3.edf (download) | 273.0 MB | 2018-11-06 |
PN05-4.edf (download) | 178.1 MB | 2018-11-06 |
Seizures-list-PN05.txt (download) | 1.2 KB | 2020-07-08 |